Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator

Product Details
Customization: Available
Output Type: AC Three Phase
Number of Blade: Multiple-Blade
Still deciding? Get samples of US$ 849/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator
  • Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator
  • Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator
  • Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator
  • Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator
  • Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Detailed Photos
  • Wiring Diagram
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RX-KG
Rotating Shaft
Horizontal
Stress Way of Blade
Resistance
Power
<10kW
Certification
CE, ISO, RoHS
Voltage
48V-220V
Generator Type
Permanent Magnet Generator
OEM
Yes
Color
White
Transport Package
Cartons
Specification
257*140*120cm
Trademark
RX
Origin
China
HS Code
8502310000
Production Capacity
50000 Pieces/ Year

Packaging & Delivery

Package Size
260.00cm * 140.00cm * 120.00cm
Package Gross Weight
180.000kg

Product Description

Product Description

Free Energy Professional Horizontal Wind Turbine 10KW 50KW Wind Generator

 1.Low start up speed; high wind energy utilization; beautiful appearance; low vibration.
2.Human friendly design, easy installation, maintenance and repair.
 
3.Precise injection molding blades together with the optimized design of aerodynamic contour and structure, the blades have such advantages: high utilization of wind energy which contributes to the annual energy output.
 
4.The generators, adopting patented permanent magnet rotor alternator,with a special kind of stator design, efficiently decrease resistance torque.Meanwhile, it makes the wind turbines match the generators quite well and increase its reliability.


Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator
 
Specification
Model
RX-G10k
Rated power
10100W
Rated voltage
48V/96V/120v/220v
Start up wind speed
2.5m/s
Rated wind speed
11m/s
Max wind speed
35m/s
Gross weight
170kg
Blades length
1.55M
Tower height
6m
Tower type
Guyed tower
Blades quantity
3
Blades mater
Nylon/glass fiber reinforced plastics
motor
Three-phase ac permanent magnet synchronous generator
Protection method
Electromagnetic brake/mechanical yaw
Work temperature
-40ºC-80ºC
 
Detailed Photos

Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind GeneratorFree Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator



 
Wiring Diagram

Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind GeneratorFree Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator

 
Company Profile

Free Energy Professional Horizontal Wind Turbine 10kw 50kw Wind GeneratorFree Energy Professional Horizontal Wind Turbine 10kw 50kw Wind Generator

 
FAQ
1. What kind of region can be installed wind turbine?
Small wind turbines should be applied in the regions which wind resources is sufficient. The annual average wind speed should be
more than 3m/s, the effective wind speed 3-20m/s should be more than 3000h in accumulation per year. The density of 3-20m/s
effectively average wind power should be more than 100W/m2.

It should be noted that choosing the rated design speed wind turbine is in conformity with local design speed. It is significantly
in making use of wind resources and in economic aspect. Wind tunnel test proves that the fan power transformation of the impeller
in the direct ratio with wind speed, that is to say, the wind speed decide the output electrical power.

2. How to calculate the actual need power in my home to configure the appropriate power of wind turbines?
At present, battery stores the power from the wind turbine, then discharge to home appliances. So the power which discharged to
the load and be charged timely by wind turbine is the amount of the actual needs power.

Take an example: the rated output power from wind turbine generator is 100W per hour, the continuous workable hours by wind is 4
hours. The battery can be charged total capacity is 400WH. For only about 70% power from battery can be discharged to the load, so
the actual power which can be used from battery is 280WH.

If there are:

1) Bulb15W x 2 Pieces, working 4 hours one day, consumption 120WH

2) TV 35W x 1 set, working 3 hours one day, consumption 105WH

3) Radio 15W x 1 Piece, working 4 hours one day, consumption 60WH

Above total consumption is 285WH per day. If you

only design to install 100W wind turbine generator, the consumption total power
will more than the power from wind turbine generator. In long period of time using power from 100W wind turbine generator, it will
make the battery serious loss of electricity and damaged, and it will cut down your battery service life.

It is assumed that wind turbine at rated wind power generation and energy consumption, but in fact, due to the variability of the
wind, intermittent, there are strong and weak wind different (wind speed) and wind blow in long time and short time
different(frequency). So you should cut down even cut off some electrical application working time when the wind condition is in
poor to protect your battery. If your budget is enough, it will be better to install a diesel generator set or install solar
panels at the same time.

3. How to select the correct battery capacity to get power from wind turbine generator?
Generally, the battery capacity should be equal or smaller than the power from wind turbine generator.

1) 100W wind turbine generator matches 120AH battery (60AH x 2 Pieces)

2) 200W wind turbine generator matches 120-180AH battery (60 OR 90AH x 2 Pieces)

3) 300W wind turbine generator matches 240AH battery (120AH x 2 Pieces)

4) 750W wind turbine generator matches 240AH battery (120AH x 2 Pieces)

5) 1000W wind turbine generator matches 360AH battery (60AH x 3 Pieces)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier