Free Energy Low Speed 5kw 10kw Permanent Magnet Generator

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 10years
Still deciding? Get samples of US$ 2175/Set
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Free Energy Low Speed 5kw 10kw Permanent Magnet Generator
  • Free Energy Low Speed 5kw 10kw Permanent Magnet Generator
  • Free Energy Low Speed 5kw 10kw Permanent Magnet Generator
  • Free Energy Low Speed 5kw 10kw Permanent Magnet Generator
  • Free Energy Low Speed 5kw 10kw Permanent Magnet Generator
  • Free Energy Low Speed 5kw 10kw Permanent Magnet Generator
Find Similar Products
  • Overview
  • Product Description
  • Recommended for
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RX-PMG450
Output Type
AC Three Phase
Rotating Shaft
Vertical
Power
<10kW
Certification
CE, ISO, RoHS, Ukca
Rated Power
1kw
Output Voltage
48V
Generator Type
Permanent Magnet Generator
Used for
Motor/Wind/Water Genreator
Weight
70kg
Rated Speed
300rpm
Structure
Inner/Outer Rotor
Rated Current
20A
Shaft. Diameter
60mm
Insulation Resistance
100mohm Min(500V DC)
Housing Material
Aluminum ( Alloy )
Shaft Material
Steel
Efficiency
>95%
Leakage Level
<5 Ma
Transport Package
by Wooden Box
Specification
80*80*50cm
Trademark
RX
Origin
China
HS Code
8502310000
Production Capacity
50000 Pieces/ Year

Packaging & Delivery

Package Size
80.00cm * 80.00cm * 50.00cm
Package Gross Weight
70.000kg

Product Description

 

Free Energy Low Speed 5kw 10kw Permanent Magnet Generator
 
Product Description

Our disc coreless PMG have advantage in low Rated speed, Low starting wind speed, Small volume, Energy Small, Light weight,
Compact structure, High efficiency etc.

1. Coreless, anhysteresis, slotless, have low starting torque.

2. No iron loss, have high efficiency

3. Adopt unique coreless precision winding technology design precision coil

4. Adopt the rare earth permanent magnet, which is multiple, mean gap, high power density and high output power.

5. Low speed direct driving, no torque fluctuations

6. Compact structure, high ratio of power to volume

7. No iron loss, low calorific value, small temperature rise

8. Simple structure, easy to install

9. The brushless structure, free maintenance

10. Application for vertical axis wind turbine, gasoline generator
s, hydroelectric generator

 

Recommended for

--Household,Garden,Farm,Urban,Rooftop
--Telecom sites
--Rural electrification programs.Island,sentry,island,sight lighting
--Automatic speed reduction protection

Product Parameters
NO.
PARAMETER
UNITS
DATA
1
Rated power
KW
1
2
Rated speed
RPM
100
3
Rated voltage
V
48V
4
Rated Current
 
20A
5
Efficiency
 
>95%
6
Resistance (Line-Line)
 
-
7
Winding type
 
Y
8
Insulation Resistance
 
100Mohm Min(500V DC)
9
Leakage level
 
<5 ma
10
Start torque
N/M
<0.3
11
Rated Torque
N/M
95
11
Phase
 
Three phase
13
Structure
 
inner rotor
14
Stator
 
coreless
15
Rotor
 
Permanent magnet type (outer rotor)
16
Gen. Diameter
mm
450
17
Gen. Length
mm
286
18
Gen. Weight
kg
58
19
Shaft. Diameter
mm
60
20
Housing Material
 
Aluminum ( Alloy )
21
Shaft Material
 
Steel
 
Detailed Photos


Free Energy Low Speed 5kw 10kw Permanent Magnet GeneratorFree Energy Low Speed 5kw 10kw Permanent Magnet GeneratorFree Energy Low Speed 5kw 10kw Permanent Magnet GeneratorFree Energy Low Speed 5kw 10kw Permanent Magnet Generator





 
Company Profile

Free Energy Low Speed 5kw 10kw Permanent Magnet GeneratorFree Energy Low Speed 5kw 10kw Permanent Magnet Generator

FAQ

 

1. What kind of region can be installed wind turbine?
Small wind turbines should be applied in the regions which wind resources is sufficient. The annual average wind speed should be
more than 3m/s, the effective wind speed 3-20m/s should be more than 3000h in accumulation per year. The density of 3-20m/s
effectively average wind power should be more than 100W/m2.

It should be noted that choosing the rated design speed wind turbine is in conformity with local design speed. It is significantly
in making use of wind resources and in economic aspect. Wind tunnel test proves that the fan power transformation of the impeller
in the direct ratio with wind speed, that is to say, the wind speed decide the output electrical power.

2. How to calculate the actual need power in my home to configure the appropriate power of wind turbines?
At present, battery stores the power from the wind turbine, then discharge to home appliances. So the power which discharged to
the load and be charged timely by wind turbine is the amount of the actual needs power.

Take an example: the rated output power from wind turbine generator is 100W per hour, the continuous workable hours by wind is 4
hours. The battery can be charged total capacity is 400WH. For only about 70% power from battery can be discharged to the load, so
the actual power which can be used from battery is 280WH.

If there are:

1) Bulb15W x 2 Pieces, working 4 hours one day, consumption 120WH

2) TV 35W x 1 set, working 3 hours one day, consumption 105WH

3) Radio 15W x 1 Piece, working 4 hours one day, consumption 60WH

Above total consumption is 285WH per day. If you only design to install 100W wind turbine generator, the consumption total power
will more than the power from wind turbine generator. In long period of time using power from 100W wind turbine generator, it will
make the battery serious loss of electricity and damaged, and it will cut down your battery service life.

It is assumed that wind turbine at rated wind power generation and energy consumption, but in fact, due to the variability of the
wind, intermittent, there are strong and weak wind different (wind speed) and wind blow in long time and short time
different(frequency). So you should cut down even cut off some electrical application working time when the wind condition is in
poor to protect your battery. If your budget is enough, it will be better to install a diesel generator set or install solar
panels at the same time.

3. How to select the correct battery capacity to get power from wind turbine generator?
Generally, the battery capacity should be equal or smaller than the power from wind turbine generator.

1) 100W wind turbine generator matches 120AH battery (60AH x 2 Pieces)

2) 200W wind turbine generator matches 120-180AH battery (60 OR 90AH x 2 Pieces)

3) 300W wind turbine generator matches 240AH battery (120AH x 2 Pieces)

4) 750W wind turbine generator matches 240AH battery (120AH x 2 Pieces)

5) 1000W wind turbine generator matches 360AH battery (60AH x 3 Pieces)

 